There are several manufacturers of this type of radiant floor heating.
Can you place radiant floor on slab on grade concrete.
Here s how to go about installing it.
Place the radiant heat tubing at the industry recommended depth down from the surface of the slab.
Moisture can pose problems for solid hardwood floors below ground level so engineered wood floors made of layers of wood glued together are the best choice there.
Secure a plywood subfloor to the concrete slab.
Basic materials for radiant floor heat installation in a slab.
Types of concrete slabs with radiant floor heating.
You simply need to embed tubing directly in the concrete no need for additional products.
The fact remains that installing radiant tubing within a concrete slab is probably the easiest most cost effective and highest performance application of the science.
Not only are you using less concrete than if pouring a full basement slab on grade provides a great base to passively heat a home.
Remember since you will only have 1 chance to pour the concrete slab you will only have 1 chance to put the pex tubing in it.
These buildings almost always have uncovered concrete floors and benefit tremendously from the warm dry floors that radiant hydronic floor heating can provide.
Does this mean you can t get hardwood installed in those areas.
The installation of a radiant heated floor slab begins by verifying the sub grade has been properly leveled and compacted.
Hardwood installation on concrete is not as easy as you would think.
Slab on grade comes with a few green benefits which i love.
With dry concrete and the right subfloors and vapor retarders solid hardwood floors can be installed on slabs that are either on grade at ground level or above grade above ground level.
Virtually any concrete pour should contain radiant tubing even if you have no immediate plans to heat the space.
You can enjoy luxurious hardwood in your concrete areas and we re going to show you how.
For concrete floor radiant heating systems the warm water tubing or electric heating elements can either be embedded within the slab on grade anywhere from the bottom of the slab to within 2 inches of the surface depending on the design and installation technique or fastened to the top of a concrete subfloor and then covered with an overlay.
One i ve used that worked well is made by uponor.
So even if there are no existing plans for the radiant floor heating or a snow melting system installing pex tubing in it may turn out to be a good decision.
The thermal benefits are unsurpassed.
Typically the maximum depth that tubing should be placed in a concrete floor slab is 2 down from the finished floor surface.