The areas to be heated can be individually defined to match any floor blueprint.
Can i use any heat cable with ditra heat mat.
The power output is matched to the stud spacing and the cable diameter is such that it is held securely by the studs on the membrane.
Like you i wanted to use a decoupling membrane plus i like the waterproofing of ditra in the bathroom.
Schlüter ditra heat has been developed offering unique electrical underfloor heating within the uncoupling matting layer system that eradicates sticky situations measuring mistakes and self levelling and primer layers.
I have a laticrete hydro ban sheet membrane for my shower so i bought laticrete multimax lite and 253 gold.
I replaced it with 1 4 durock cement board.
Never cut or modify the heating cable in any way.
If the total current in your setup is less than 15 amps then two ditra heat e hk heating cables can be connected and controlled by a single ditra heat e rt rsd r thermostat.
Use our ditra heat calculator to find out what products you need to complete your specific installation.
Do you have any advice on if i can use these products with the ditra heat.
Schluter systems does not recommend the installation of floor warming systems over ditra or ditra xl.
This results in an integrated heating mat.
Always keep a 3 stud 3 1 2 9 cm spacing between heating cable runs.
Install heating cable systems per heating manufacturer s directions.
The ditra heat e hk heating cables are specifically designed to integrate with the ditra heat membrane.
One of the advantages of using ditra heat membrane is that you don t need to cover the cables with self leveling cement or thinset mortar before laying tiles.
Schluter ditra heat dhekrt12040 26 7 sf 120v kit includes touchscreen programmable thermostat heating cable ditra heat sheets 2 floor sensors 4 8 out of 5 stars 62 329 00 329.
I am installing a ditra heat kit.
Encapsulate heating cables in a skim coat of schluter all set fast set or modified thin set mortar or cement based leveling compound and allow to cure before installing ditra or ditra xl with schluter set or unmodified thin set mortar.
Schlüter ditra heat e is comprised of an uncoupling mat and a heating cable joint assembly height only 5 5 mm which are combined directly on site.
Ditra does not recommend using anything but their own heating cables but nuheat advertises that their cable system works just fine with the ditra heat membrane.
This would change the cable resistance will cause damage to the cable and could cause cable overheating.
Can other manufacturer s heating cables be installed with schluter ditra heat membrane.
However this also means you need to be careful with your trowel when laying tile and that you do not use a knife or sharp trowel edge to clear thinset from grout lines.
Ditra heat e is the perfect choice for retrofitting and renovations.